Magnum MMG100D Manual del operador Pagina 1

Busca en linea o descarga Manual del operador para Generadores De Poder Magnum MMG100D. Magnum MMG100D Operator`s manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 56
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Parts manuals available online! www.m-p-llc.com
POWER PRODUCTS LLC
DIESEL GENERATOR
75
MMG75D • MMG100D
OPERATING MANUAL
Vista de pagina 0
1 2 3 4 5 6 ... 55 56

Indice de contenidos

Pagina 1 - OPERATING MANUAL

Parts manuals available online! www.m-p-llc.comPOWER PRODUCTS LLCDIESEL GENERATOR75MMG75D • MMG100DOPERATING MANUAL

Pagina 2 - MAGNUM POWER PRODUCTS LLC

10SAFETY SYMBOL SUMMARYThis equipment has been supplied with numerous safety and operating decals. These decals provide important operating instructio

Pagina 3 - TABLE OF CONTENTS

11SPECIFICATIONS - MMG75DRead this manual carefully before attempting to use this generator. The potential for property damage, personal injury or dea

Pagina 4

12SPECIFICATIONS - MMG100DRead this manual carefully before attempting to use this generator. The potential for property damage, personal injury or de

Pagina 5

13UNIT DIMENSIONSRead this manual carefully before attempting to use this generator. The potential for property damage, personal injury or death exist

Pagina 6 - OPERATING SAFETY

14UNIT SERIAL NUMBER LOCATIONSRefer to the locations illustrated below to find the unit ID tag and VIN tag on your unit. Important information, such a

Pagina 7 - ELECTRICAL SAFETY

15COMPONENT LOCATIONSVoltageSelectorSwitch AccessHandleFront HoodLatchEngineExhaustFuel FillOil DrainPortRadiatorDrain PortControlPanel AccessEmergenc

Pagina 8 - TOWING SAFETY

16MAIN CONTROL PANEL FEATURES, STANDARD256791011184312AUTO EXHAUSTFILTER CLEANINGLIMPIEZA AUTOMÁTICADE FILTRO DE ESCAPEAUTOMATISCHEABGASFILTERREINIGUN

Pagina 9

171. MAIN CIRCUIT BREAKER: This breaker will disconnect power to the connection lugs (items 10-11). It WILL NOT disconnect power to the convenience ou

Pagina 10 - SAFETY SYMBOL SUMMARY

18MAGNUM DIGITAL CONTROLLER (MDC)The Magnum Digital Controller (MDC) is an enhanced digital generator controller used to start, stop and monitor the o

Pagina 11 - SPECIFICATIONS - MMG75D

19• “AUTO ” Button: Press this button to change from Manual starting mode to Automatic (remote) starting mode.• “ALARM CANCEL” Button: When an alarm

Pagina 12 - SPECIFICATIONS - MMG100D

2INTRODUCTIONThis manual provides information and procedures to safely operate and maintain the engine and generator. For your own safety and protecti

Pagina 13 - UNIT DIMENSIONS

20• Oil Pressure: Displays engine oil pressure. The display registers oil pressure between 0-100 psi (0-689 kPa). Normal operating pressure is between

Pagina 14 - UNIT SERIAL NUMBER LOCATIONS

21• “Password” screen: The operator may press the “” or “” buttons on the “DIAGNOSTICS” keypad to move the cursor (>) up or down a list of text.•

Pagina 15 - COMPONENT LOCATIONS

22• “DPF Inhib” area: This area will display the “Disabled Regeneration” indicator above the words “DPF Inhib” when auto exhaust filter cleaning is di

Pagina 16 - FILTER CLEANING

23To adjust the output voltage, check the output voltage on the generator display screen. Look at the “L1N” voltage or the “L12” voltage on the displa

Pagina 17

24 TO CLOSE THE FRONT HOOD:1. Make sure the skid is free of debris and all personnel are clear of unit. CAUTIONDo not attempt to close the hood from t

Pagina 18

25MANUAL STARTING OF THE GENERATOR1. Move the control ON/OFF toggle switch to the “CONTROL ON/I” position.DANGERCARBON MONOXIDE: USING A GENERATOR IND

Pagina 19 - ENGINE MONITORING

266. The Running screen will display. Note: It may take a few seconds for the engine to run smoothly and reach its governed operating speed. The 45 se

Pagina 20 - BINARY OUTPUTS SCREEN

27“AUTO” (REMOTE) STARTING OF THE GENERATORThe “AUTO” button is used when the generator is started from a location other than the control panel and by

Pagina 21

28EXHAUST FILTER CLEANING OPERATIONSWhen enabled, the exhaust filter system goes through an automatic cleaning process known as regeneration. Under no

Pagina 22 - FINE VOLTAGE ADJUSTMENT

29MDC CONTROLLER INFORMATION DISPLAYS, FUNCTIONS, AND RESETThe Magnum Digital Controller (MDC) constantly monitors vital generator and engine function

Pagina 23 - Figure A

3TABLE OF CONTENTSPageINTRODUCTION ...

Pagina 24 - PRE-START CHECK LIST

30MAGNUM DIGITAL CONTROLLER (MDC) - LIST OF ALARMSShutdown and warning fault conditions and the displayed message are described in the following table

Pagina 25

31JOHN DEERE ECU INFORMATION DISPLAYS AND FUNCTIONSThis unit has a John Deere Electronic Engine Control Unit (ECU) which regulates the engine speed (r

Pagina 26 - OFF MAN AUT

32*Note: The Suspect Parameter Number (SPN) is displayed as “FC” on the bottom left of the LCD window. Refer to Figure 1.MDC CONTROLLER – HISTORYThe M

Pagina 27 - SHUTTING DOWN THE GENERATOR

33ADJUSTING THE DISPLAY BACKLIGHTINGThe brightness on the Liquid Crystal Display (LCD) window may be adjusted by the operator whenever the Magnum Digi

Pagina 28

343. If the oil level is good, restart the unit and verify the loss of oil pressure. Shut the engine down immediately if the oil pressure value does n

Pagina 29

35GENERATOR OUTPUT CONNECTION LUGSThe generator is equipped with connection lugs behind the lug box door located on the lower portion of the control b

Pagina 30

36VOLTAGE SELECTOR SWITCHThe voltage selector switch is located on a panel attached to the generator behind the door located next to the fuel tank fil

Pagina 31 - Figure 1

374-POSITION VOLTAGE SELECTOR SWITCH OPTIONThe optional four position voltage selector switch is located on a panel attached to the generator behind t

Pagina 32 - MDC CONTROLLER – HISTORY

38EMERGENCY STOP SWITCHThe generator is equipped with one emergency stop switch, located on the right rear corner of the unit next to the control door

Pagina 33

39CUSTOMER CONVENIENCE OUTLETSThe generator is equipped with five convenience outlets. The large outlets are 240/120VAC twist-lock receptacles rated a

Pagina 34

4FUEL TRANSFER PUMP OPTION ... 45VISCOUS FAN CLUTCH OPTI

Pagina 35 - RUN CABLES THROUGH SLOTS

40TRANSFER SWITCHWhen the generator is used as a standby power supply, it must be equipped with a transfer switch which isolates it from the utility’s

Pagina 36 - VOLTAGE SELECTOR SWITCH

41BELT TENSIONJohn Deere engines use two types of belt tensioners: manual and automatic. Adjust the belt using the manual tensioner according to the m

Pagina 37

42• Never wash the engine block or fuel tank with a power washer or steam cleaner. Water may enter the cabinet and collect in the generator windings o

Pagina 38 - VOLTAGE REGULATION

43 * Replace primary air cleaner when dust valve restriction indicator gauge shows a vacuum of 25 in. H2O. ** Change the oil and oil filter after the

Pagina 39 - REMOTE START TERMINAL BLOCK

44LIFTING THE GENERATORA large central lifting eye is located on the top of the generator. The eye is connected to a central lifting frame inside the

Pagina 40 - TRANSFER SWITCH

45CHECKING GENERATOR DRIVE PLATE TORQUEFollow the procedure below to check the torque of the generator drive plate bolts in accordance with the mainte

Pagina 41 - AUTO EXERCISE TIMER

46VISCOUS FAN CLUTCH OPTIONThe viscous fan clutch option allows the engine cooling fan to engage at lower speeds, and disengage at higher speeds, incr

Pagina 42 - DAILY WALK AROUND INSPECTION

47AC WIRING DIAGRAM - 3 POSITION VOLTAGE SELECTOR SWITCHBREAKER240V 50ABRN 240V 50ABREAKER240V 50ABREAKERBLK BLK BLK BLK BRN 5913610 147811121516T5BLK

Pagina 43 - ENGINE BREAK-IN REQUIREMENTS

48AC WIRING DIAGRAM - 4 POSITION VOLTAGE SELECTOR SWITCH OPTIONBRNGRN/YEL 10GA(T7)CT-3L2L3SHUNTL1CT-2CT-1BREAKERGRN/YEL 14GAGRN/YEL 10GAGRN/YEL 10GA(2

Pagina 44 - Central Lift Eye

49AC WIRING DIAGRAMS FOR OPTIONAL EQUIPMENTCIRCUITBREAKERCAMLOCKPANELGNDL0L1 L3L265872VOLTAGE RELAYH1 H3X2X4 X1X3H2 H4BLK RED POWERRELAYBLKBLKWHTWHTWH

Pagina 45 - FUEL TRANSFER

This Page Intentionally Left Blank5

Pagina 46 - VISCOUS FAN CLUTCH OPTION

50DC WIRING DIAGRAMPLUG LOCATIONRPMPINRPM INRPM GNDMAG INMAG REFD+PLUG LOCATIONPOWER + DC+RELAY BOARDD+LOWERE STOPBI17 PIN PLUG (BINARY INPUTS)BO1C1 +

Pagina 47 - 90250_A_03.13.13

51DC WIRING DIAGRAMS FOR OPTIONAL EQUIPMENTJHDEUTSCH21 PIN CONN-2EDISON PLUG16/3BRNBLUYEL/GRNFANCLUTCHRELAYTOCONTBO7BOTTOMPINE STOPBI16 PIN PLUG (BINA

Pagina 48 - 90296_A_10.26.12

52WIRING BLOCK DIAGRAM - DEDICATED 12 LEAD GENERATORS OPTIONLOL3 L2 L1TO CONTROL BOXLOL3 L2 L1TO CONTROL BOXLOL3 L2 L1TO CONTROL BOXLOL3 L1TO CONTROL

Pagina 49 - 90415_E_03.19.13

53TRAILER WIRING DIAGRAMTRAILER PLUGTRAILER PLUGGNGNBKBKYLYLBNBNBNBNWTWTLAMPMARKERAMBERWTWTWTWTAMBERMARKERLAMPBKBKWTWTREDMARKERLAMPBKBKBKBKLAMPMARKERW

Pagina 50 - DC WIRING DIAGRAM

54WIRING HARNESS - ELECTRIC BRAKE OPTION90286_D_10.31.12BATTERYBREAKAWAYSWITCHBLUWHT BLKWHT WHTWHTWHTBRAKEBLUBLUBRAKEWHTBLU BLUBLUBLUWHTBRAKEBLUBLUBRA

Pagina 51 - INTERIOR

55SERVICE LOGOIL GRADE AND TYPE: ___________________________ BRAND: ___________________________________COOLANT MIXTURE: ____________________________

Pagina 52 - 90302_A_11.06.12

REV: BPART NO: 3266803.15.13

Pagina 53 - TRAILER WIRING DIAGRAM

6SAFETY NOTESThis is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this

Pagina 54 - 90286_D_10.31.12

7ENGINE SAFETYInternal combustion engines present special hazards during operation and fueling! Failure to follow the safety guidelines described bel

Pagina 55 - SERVICE LOG

8TOWING SAFETYTowing a trailer requires care! Both the trailer and vehicle must be in good condition and securely fastened to each other to reduce t

Pagina 56 - 03.15.13

9REPORTING TRAILER SAFETY DEFECTSIf you believe your trailer has a defect which could cause a crash or could cause injury or death, you should immedia

Comentarios a estos manuales

Sin comentarios