32
*Note: The Suspect Parameter Number (SPN) is displayed as “FC” on the bottom left of the LCD window. Refer to
Figure 1.
MDC CONTROLLER – HISTORY
The Magnum Digital Controller (MDC) stores a record of each important event into the history file of the controller.
The history file seats 117 records. When the history file is full, the oldest records are removed.
9 SPN:651 InjectorCyl#1
10 SPN:652 InjectorCyl#2
11 SPN:653 InjectorCyl#3
12 SPN:654 InjectorCyl#4
13 SPN:655 InjectorCyl#5
14 SPN:656 InjectorCyl#6
15 SPN:677 EngStartRelay
16 SPN:1485 ECU MainRelay
17 SPN:3719.15 High soot load caution
18 SPN:3719.16 Very high soot load warning
19 SPN:3719.00 Very high soot load - needs service
No.
Record Structure
Abbreviation
Historical Value
1 AIM1 IG-IOM, IGS-PTM analog input 1 value (when configured IG-IOM, IGS-PTM)
2 AIM2 IG-IOM, IGS-PTM analog input 2 value (when configured IG-IOM, IGS-PTM)
3 AIM3 IG-IOM, IGS-PTM analog input 3 value (when configured IG-IOM, IGS-PTM)
4 AIM4 IG-IOM, IGS-PTM analog input 4 value (when configured IG-IOM, IGS-PTM)
5 BIM IG-IOM, IGS-PTM binary inputs (when configured IG-IOM, IGS-PTM)
6 BIN Binary inputs IL-NT
7 BOM IG-IOM, IGS-PTM binary outputs (when configured IG-IOM, IGS-PTM)
8 BOUT Binary inputs IL-NT
9 Date Date of historical event in format DD/MM/YY
10 EngT IL-NT analog input 2 value (default: water temperature)
11 FC ECU alarm FailureCode
12 FLvl IL-NT analog input 3 value (default: fuel level)
13 FMI ECU alarm failure mode identifier
14 Gfrg Generator frequency
15 Ig1 Generator current L1
16 Ig2 Generator current L2
17 Ig3 Generator current L3
18 LChr Character of the load
19 Num Number of historical event
20 OilP IL-NT analog input 1 value (default: oil pressure)
21 PF Generator PF
22 Pwr Generator active power
23 Reason Event specification
24 RPM Engine speed
25 Time Time of historical event in format HH:MM:SS
26 Ubat Battery voltage
27 Vg1 Generator voltage L1
28 Vg2 Generator voltage L2
29 Vg3 Generator voltage L3
No. SPN Description